Call us – 0330 520 2709

Sample report

Scroll through a full report pack

This is a worked sample of the documentation you receive after every A-Grade extraction clean — all 14 sections, exactly as issued.

A-GRADE

Industrial Cleaning

Extraction Clean Report

Page 1 of 14

EXTRACTION CLEAN REPORT

Commercial kitchen extraction system — full documentation pack

Site

Sample shown

System cleaned

Full extraction system

Date of clean

Sample shown

Report ref

AG-XXX-XXXX

Engineer

Sample shown

Next clean due

See page 13

What's inside: scope of works, methodology, grease readings, photographic evidence, recommendations, compliance certificate and the next-clean schedule.

A-GRADE

Industrial Cleaning

Scope of Works

Page 2 of 14

Areas included in this clean

  • ✓Canopy interior and exterior, including grease gutters and channels
  • ✓Canopy plenum and grease filters — removed, degreased and refitted
  • ✓All accessible horizontal ductwork runs via access panels
  • ✓Vertical riser ductwork from canopy to fan connection
  • ✓Extraction fan — blades, housing and surrounding ductwork
  • ✓Disinfection of all cleaned surfaces and full debris removal

Scope confirmed against the system survey carried out before the clean.

A-GRADE

Industrial Cleaning

Methodology & Access

Page 3 of 14

How the clean was carried out

  • ✓System isolated and made safe before work begins
  • ✓Filters removed and degreased in soak tanks on site
  • ✓Canopy and plenum hand-degreased and pressure-rinsed
  • ✓Ductwork cleaned through existing and cut access panels
  • ✓Fan opened, blades and housing cleaned, guards refitted
  • ✓All waste grease removed from site — nothing left on premises

Access panels used

Existing + new

Waste removed

Yes — off site

Kitchen returned

Same day

A-GRADE

Industrial Cleaning

Residual Grease Readings — Canopy

Page 4 of 14

Canopy & plenum

Canopy interior — centre linePass
Canopy interior — perimeterPass
Plenum — rear of filtersPass
Grease gutter & channelsPass
Filter housing framePass

Readings taken at every test point after the clean — no residual grease detected.

A-GRADE

Industrial Cleaning

Residual Grease Readings — Ductwork

Page 5 of 14

Horizontal ductwork runs

Access panel A1 — canopy plenumPass
Access panel A2 — horizontal runPass
Access panel A3 — mid-runPass
Access panel A4 — run endPass

A-GRADE

Industrial Cleaning

Residual Grease Readings — Riser & Fan

Page 6 of 14

Vertical riser & extraction fan

Access panel B1 — vertical riserPass
Access panel B2 — fan connectionPass
Fan housing interiorPass
Fan bladesPass

Result: system clean throughout — compliant on completion.

A-GRADE

Industrial Cleaning

Photo Evidence — Canopy

Page 7 of 14

Photographic evidence

Canopy plenum — before
Canopy plenum — before
Canopy plenum — after
Canopy plenum — after

Photos taken on site, dated and filed against this report reference.

A-GRADE

Industrial Cleaning

Photo Evidence — Fan Blades

Page 8 of 14

Photographic evidence

Fan blades — before
Fan blades — before
Fan blades — after
Fan blades — after

A-GRADE

Industrial Cleaning

Photo Evidence — In-Duct Fan

Page 9 of 14

Photographic evidence

In-duct fan — before
In-duct fan — before
In-duct fan — after
In-duct fan — after

A-GRADE

Industrial Cleaning

Photo Evidence — Roof Fan & Riser

Page 10 of 14

Photographic evidence

Roof fan — before
Roof fan — before
Roof fan — after
Roof fan — after
Vertical riser — before
Vertical riser — before
Vertical riser — after
Vertical riser — after

A-GRADE

Industrial Cleaning

Defects & Recommendations

Page 11 of 14

Findings raised to site management

Access panel A3 — stiff hingeRecommendation
Access panel B1 — seal wornRecommendation
Fan guard fixings — corrodedRecommendation

Recommended actions

  • Ease and re-lubricate access panel A3 hinge — minor, can be done at next visit.
  • Replace worn seal on panel B1 to keep duct airtight between cleans.
  • Replace corroded fan guard fixings — quoted separately, optional.

A-GRADE

Industrial Cleaning

Access Panel Schedule

Page 12 of 14

Panels installed / verified on this system

A1 — Canopy plenumExisting
A2 — Horizontal run — startExisting
A3 — Horizontal run — midExisting
A4 — Horizontal run — endExisting
B1 — Vertical riser — lowExisting
B2 — Fan connectionExisting

Every panel is photographed and labelled so future cleans can reach the whole system.

A-GRADE

Industrial Cleaning

Compliance Certificate

Page 13 of 14

Certificate of Extraction Clean

This certifies that the kitchen extraction system at the site named on page 1 was cleaned to the standard described in this report on the date of clean shown above.

Signed

Sample shown

Date

Sample shown

Retain this certificate for your fire risk assessment records

Insurers, fire risk assessors and environmental health officers can be directed to this certificate.

A-GRADE

Industrial Cleaning

Next Clean & Sign-Off

Page 14 of 14

This clean

Sample shown

Next clean due

Sample shown

Frequency agreed

Sample shown

Sign-off

A-Grade engineer

Sample shown

Site representative

Sample shown

Both parties sign on completion — the kitchen is handed back clean, safe and documented.

End of report — thank you for choosing A-Grade Industrial Cleaning.

Worked sample — site details are anonymised. Your report will carry your own site information, dates and photos.